Place of Origin |
Zhejiang China (Mainland) |
Brand Name |
DHECN |
Model Number |
HDR-120 |
Input Voltage |
220V |
Output Voltage |
12V/24/48V |
Output Current |
10A/5A/2.5A |
Output Power |
101 - 200W |
Output Type |
Single |
switch power supply Features: Universal AC input / full range Protections: Short circuit/ Over load/ Over voltage/ Over temperature Cooling by free air convection Can be installed on DIN rail TS-3.5/7.5 or 15 LED indicator for power on 100% full load burn-in test Fixed switch frequency at 55KHz 1year warranty Dimensions: 65.5*125.2*100mm (W*H*D) MODEL HDR-120-12 HDR-120-24 HDR-120-48 DC VOLTAGE 12V 24V 48V VOLTAGE TOLERANCE ±2% ±1% ±1% RATED CURRENT 10A 5A 2.5A CURRENT RANGE 0-10A 0-5A 0-2.5A RATED POWER 120W 120W 120W RIPPLE & NOISE 80mVp-p 80mVp-p 100mVp-p DC ADJUSTMENT RANGE 12-14V 24-28V 48-53V SETUP, RISE 500ms,70ms/230VAC at full load 500ms,70ms/115VAC at full load OUTPUT HOLD TIME 36ms/230VAC 32ms/115VAC at full load VOLTAGE RANGE 88132 VAC/176 264VAC 4763 Hzselected by 248370VDC AC CURRENT 2.6 A/115 V 1.6A/ 230 V EFFICIENCY 80% 84% 85% INRUSH CURRENT Cold start 20A/115V 40A/230V INPUT LEAKAGE CURRENT 3.5mA/240VAC 105%150% OVER LOAD Protection type: Constant current limiting, recovers automatically after fault condition is removed 120% 135% OVER VOLTAGE Protection type: Shut down o/p voltage, re-power on to recover 85±5(TSW1) 90±5(TSW1) 90±5(TSW1) PROTECTION OVER TEMP. Protection type: Shut down o/p voltage, recovers automatically after temperature goes down WORKING TEMP., HUMIDITY -10+6020%90 %RH STORAGE ENVIRONMENT TEMP., HUMIDITY -20+8510%95 %RH VIBRATION 10500Hz,2G 10min./1cycle, period for 60min, each along X, Y, Z axes WITHSTAND VOLTAGE I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC SAFETY ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC SAFETY STANDARD Design refer to UL508,UL60950-1,TUV EN60950-1 STANDARD EMC STANDARD Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11, ENV50204,EN55024, EN61000-6-2(EN50082-2) WEIGHT 0.79Kg OTHERS PACKING 20pcs/16.5Kg/1.1CUFT NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12twisted pair-wire terminated with a 0.1μ& 47μ parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.